By pressing the sun button, you can reach the settings you need to control your heating and hot water during the day. Had our swift challenger se for 4 months now, with alde 3010 heating system. Alde International Systems AB is a world-leading company which develops, produces and markets heating systems for caravans and motorhomes. Make sure the red bypass handle is not in bypass mode, if that is ok These are the steps required to get hot water if you are on an electric hook-up i.e. THE ELECTRICAL HEATING CARTRIDGE DOES NOT WORK Cause: - Check that the changeover switches on the control panel are in the correct positions (see operating instruction for boiler). No match Heater/Panel: The circuit board in the boiler is not intended for the Alde Compact 3020 HE and will not work with the 3020 HE panel… We as owners know much more about the Alde than most dealers. 2018 TaB400 Boondock, Jeep Gladiator truck, Northern California Coast. Alde Smart Control Alde Flow Alde Comfort 2928 Alde Comfort 2925 Alde Comfort 2923 Alde Comfort 2921 Alde Comfort 2920 Alde 2900 / 2910 Electric heater Engine heat exchanger 2968 ... Alde Heating System Our Accessories Products Manuals About Alde Service and Support FAQ Find service location Much better than previous caravan with blown air heating. Alde System: Control Panel. Unplug the TV and back surge happens as the systemic current looks for a new ground, goes up the negative wire of the Alde, even connected to the negative battery terminal, and burns the fuse. And unfortunately the weak link to all of this is the fuse at the Alde. The mixing valve on the 320 S and CS is now located under the driver side bench behind/near the Alde, exterior shower hoses and Nautilus. The blue valve This should not affect how the control panel works in relation to the pump. Service Manual Compact 3010 This a 12-volt thermostat on the control panel. I would wait a half hour and see if your water is hot enough. By that point the camper was starting to turn into a sauna. The boiler is so ingeniously designed that in the first instance it selects the immersion heaters as primary heat source if 230 V is connected to the vehicle and if the immersion heaters are activated on the control panel. I contacted Alde and they were excellent, responded within 15 minutes to the email. I had to unscrew the knob abd manually turn the stalk out about a turn then put the knob back on. The Alde provides two things: hot water for the shower and sink, and also cabin heat. Can you take a picture of your Alde settings? I never had one, but had those fuses on hand. Indeed, 1 kW may not be sufficient power to heat a caravan in cold weather. The Compact 3020 HE can generally be installed wherever you want. In my case, it wasn’t enough. Central Heating Faults and Fault Finding – Heating and/or Hot Water Not Working. Not sure where you access those on a 21, previously they were both obvious right inside the outside door on on rear of driver side. Makes it simple to control the heating system and has smart … Control of the boiler is via a processor on the boiler’s circuit board. Had a mystery with our Alde central heating heating which would not run. That way, any negative electrons not accepted by the fully charged battery flow into the chassis, instead of traveling up the Alde ground wire to the fuse. During that time, I too experienced the control panel ceasing to work, and had to replace the glass fuses on top of the Alde unit—primarily the one on the negative 12V side—four times, until I fixed the problem. This may not have been your problem but something to bear in mind. Had our swift challenger se for 4 months now, with alde 3010 heating system. Alde suggested the following which solved the problem I know this sounds absurd, but this is all I can figure out at this point. The boiler is so ingeniously designed that in the first instance it selects the immersion heaters as primary heat source if 230 V is connected to the vehicle and if the immersion heaters are activated on the control panel. The … One blue, one red. It is like trying to pour water down a pipe into a full cup. Do you have cold water coming from the hot tap? The mixing valve on the 320 S and CS is now located under the driver Sometimes, the fuse would form a little globule on it, and still work connected to the TV, but not when unplugged from the TV. The Alde's "brain" (control panel, internal fan, and sensors, and internal circuits) all work on 12V regardless of whether the Alde is plugged in or not. I think this is the best explanation for the mixing valve per Bayliss. The heating elements require 120V AC or propane to operate. 1:0 ABOUT THE ALDE CENTRAL HEATING 12 7:0 Electrical diagram with control panel 13 We have recently purchased a TAB 400 and the instructions regarding hot water do not seem clear. The heart of the issue is having a good enough ground system to avoid back surge blowing the 3.15 amp fuse on the Alde 3010 ground wire. Edit to note you have a If you do, be careful as it is easy to go too far and you end up with a flood. Alde International Systems AB is a world-leading company which develops, produces and markets heating systems for caravans and motorhomes. I did that, and moved the negative wire from the Alde 3010 off the negative bus bar and directly on to the battery negative terminal. I should clarify as well, that I always had the Alde turned off for all location moves or power changes, so that was never the issue. Above: The Alde control panel on its highest temperature setting. When it is fully charged, there is not much space in it to draw negative electrons (the resistance is too high). I will say the dealer I purchased this from did not give me a proper education on how much tweaking the system requires. Hi All The control panel for my Alde combi heating/water has stopped working, with the result that I cannot turn on or control the heating/hot water. However, 12V DC (either from the battery or the converter) is required to run the Alde's operational circuitry, regardless of whether you are heating with 120V AC or propane. Alde’s Battery Backup unit comprises a 2 x AA battery holder and the means to plug it into the rear of the control panel. Check under the bunk where the unit is located, Nd see if the 129VAC cord is plugged in, check fuses, etc. I contacted Alde and they were excellent, responded within 15 minutes to the email. And if not, you can call out a professional plumber or heating engineer to help – which we advise if you are at all unsure with carrying out any of the possible remedies described below. https://tab-rv.vanillacommunity.com/discussion/2676/little-hot-water/p1, https://tab-rv.vanillacommunity.com/discussion/11579/drains-under-the-2021-tab-320-s#latest, https://tab-rv.vanillacommunity.com/discussion/5018/no-hot-water-at-kitchen-sink-bathroom-sink-had-hot-water#latest. It only took me ten fuses to arrive at this point! I did pull up on the yellow flapper valve last night before I called it a day. It’s all pretty much self-explanatory as for as the heat for the camper itself. But when I pull a certain plug on the pcb the pump start up for a few seconds small click then the pump stops tryed two PCB but we do have hot water no 12v to circulation pump any ideas would be most welcome ps the plug I pull was just above the thermo fuse. You need access to the rear of the control panel because the wiring harness must be inserted into it – some dismantling may be necessary to do this. They release water down to the ground. BE AWARE OF THE RISKS OF 230 V DURING ALL SERVICE WORK FAULTFINDING Fig 1. Also, going through all this again today, and after having flipped up the safety valve last night, I did get a lot of sputtering from the hot water tap, and a lot of sputtering noises coming from the boiler as well. The blue valve releases cold water, and right now the red valve is releasing lukewarm to warmish water, not hot at this point. Brrr, getting a bit cool now, how do I turn the heating on to override the night temperature setting? Unfortunately, where we are in France is rather devoid of Alde service centres so we cannot get the panel tested easily. ". The solution is to ground the trailer battery to the trailer chassis, and connect the Alde ground wire to the same chassis ground terminal. I did and better half had to use tweezers to get it back. That is usually inside the door or under a front bed. Also, my Tab 400 chassis is constructed of pre-painted C channel and bracing, all riveted together. turn on the propane at the tank and turn on the Alde Control Panel. I need to see the 2021under bench valve configuration. The Kontiki has two accessories in place – one is the Alde load monitor and the other is the battery back up device for the clock and timer. I have owned a Tab 400 for a year now, put 13,000 miles on it, and used it off and on for about two months of total travel. - No or low voltage to the boiler. The explanation is that the negative side of the battery itself is insufficient to prevent back surge. Don’t expect your heating system to warm the van through instantly. As well as noticing a lack of heat or hot water within your household, there are some additional common boiler problems to look out for, including: Unusual whistling, banging, or tapping noises; Higher than average gas usage indicates the boiler is not performing efficiently This function makes it possible to have fully automated climate control for both heating, cooling and hot water. Which the Alde running on gas or electric (electric needs a 20 amp minimum connection), check the Alde vent on the outside of the trailer next to the Nautilus door, you should feel heat coming out, if not, than the Alde is not working. Used the same procedure as M_Mich, but others using it have had issues. The Alde control panel, the stereo system and the carbon monoxide alarm all use a little power even when "off," and the refrigerator uses more when on while I travel. side bench behind/near the Alde, exterior shower hoses and Nautilus. The control panel also features a user-friendly interface, with self-explanatory menus in colour. It was a warm day and they just wanted hot water for the taps and shower. Not sure what you mean by "the red bypass handle". A/ on the control panel select the system to ON. This Alde system appears to require a lot of hands on effort to maintain in proper working order. If this is not enough, the LPG burner starts automatically (if this is activated in the control panel). Please help!! I know where both the mixing valve and the bypass valve are located. 3:1 THe eLeCTrICAL HeATING CArTrIdGe doeS NoT worK Cause: - Check that the changeover switches on the control panel are in the correct positions (see operating instruction for boiler). Welcome to the forum and thanks for the information you have provided! If not then adjust the mixing valve. I do hope nuCamp has sorted this out and are putting the proper wire gauge and fuses in the current models. That might be a problem only for a subset of early 400s pulled by trucks. The 3010-615 offers an improved user interface with a … Gremlins, I tell you!!!! During that time, I too experienced the control panel ceasing to work, and had to replace the glass fuses on top of the Alde unit—primarily the one on the negative 12V side—four times, until I fixed the problem. You can find us at some of the world’s leading trade fairs – or maybe when you’re staying in one of the fabulous recreational vehicles available on the market. I have a 2018 320 CS-S. Here is the mixing valve thread with a description of what it is and what it does. This is a replacement for the original control panel and offers the latest touch sensitive technology. The sputtering was air you introduced into the system. Well, I have to somewhat sheepishly amend my long-winded explanation, with another long-winded explanation. When you take it out don’t drop it! The fuses are fine etc. 1:0 ABOUT THE ALDE CENTRAL HEATING SYSTEM CONTENTS Page Chap Designation It did release a quantity of air (the manual indicates that this is necessary to produce an "air cushion". The Alde Heating System. It looks like you're new here. You need access to the rear of the control panel because the wiring harness must be inserted into it – some dismantling may be necessary to do this. When we changed our van to one with the Alde heating/water system, this is what we found: a) The van seemed to take longer to heat up, but this was deceptive, as the whole fabric was warming, not just the air as it was with the Truma fire and blown air system. Run would be about 6 feet. That's why those pesky little glass fuses leave the unit dead in the water when one of them blows! You can find us at some of the world’s leading trade fairs – or maybe when you’re staying in one of the fabulous recreational vehicles available on … The control panel for the Alde System is located in the galley right above the sink. Use this step by step guide to central heating fault finding and fault repair and identify why your hot water or heating is not working quickly and easily. However, they were having real trouble working with the control to get just hot water and not space heating. Only difference is location, they both The Alde system is being installed these days on more and more RVs, especially Roadtreks, so it might be useful to explain what an Alde system is and how it works. The circuit voltage imbalance is the culprit and I think that anyone who has owned a. I follow the same routine as Mike, above, which makes good sense! This tells me that either (1) the boiler is heating an empty tank, because no water is able to fill it up, or (2) there is water in the tank that is heating up, but somehow it is not being released into the plumbing to the taps. Whatever that is, I've not touched it, and it remains in whatever position it was in when it came fro the factory. (1 kW is about a third of the power of a domestic kettle.) How long has the Alde been on? It’s different (maybe) Because of the Nautilus. Please help!! Sometimes gets loose. nr 3020023) allows access to the following premium functions: Control of the floor heating pump. I did not test to see if it formed a unified ground, although, in retrospect, I should have, since I doubted it would. No match Heater/Panel: The circuit board in the boiler is not intended for the Alde Compact 3020 HE and will not work with the 3020 HE panel. heat up the air, which rises and warms the walls and furniture. The Alde battery backup kit is a simple device that can be fitted to retain the control panel settings such as time, date and other parameters when the vehicle’s main switch is off. Its generally seen as not a very user-friendly control panel. Alde International Systems AB is a world-leading company which develops, produces and markets heating systems for caravans and motorhomes. have a bypass and mixing valve and the Alde itself is same unit AFAIK. Hi People. - 230 volt not connected. Alde heating control panel not working. Mine did, but i just pushed back and screwed it in a couple of turns. I'm not sure why, but some people have issues with the fusing. They release water down to the ground. Brrr, getting a bit cool now, how do I turn the heating on to override the night temperature setting? I chose a spot in an overhead locker, at the end of which the control panel was fitted. As the warm air rises, it forms an air-barrier which prevents cold from the windows entering. If you would like to test control panel and its functions, click here. Contact Kanga Products for a pre built battery backup - for Alde control panels. This did indeed solve the issue of back surge when the trailer was plugged in or unplugged from 120 AC. If this is not enough, the LPG burner starts automatically (if this is activated in the control panel). B/ Set the Internal Temperature setting lower than the ambient temperature (I set mine to 10C) this stops the pump running and hence no heating is provided. You did follow the instructions to set the mixing valve right? The temperature inside the caravan is controlled by a 12-volt thermostat on the control panel. An electrical engineer could calculate if one side piece of chassis was enough additional ground, not welded to the rest. I read the Alde install manual and they say 16awg from the battery to the unit if the run is less than 65ft. tonyidle Here is a control panel simulator to play with, https://control-panel.alde.se/settings on this the shower symbol will go to nothing "blue" which to me would be hot water off so if the heating is off the hot water will be off as well, as established above you can't have the hot water off with the heating on as it heats by default. I had a look at the Alde control panel and even I couldn’t work it out, and I generally regard … Check. Given that the boiler works fine on gas and that the indicator isn't showing on the control panel then it's a mains supply issue, so nothing to be gained by checking/swapping 12 volt fuses. The fancy Swift colour control panel seems lacking in some vital functions. Not easy when you are away. Why? 320, and I answered for a 400. Hello. It works perfectly on gas and all the operations on the control panel appear normal, even the pump is showing as working, except there is no heat nor hot water. How do you fill the hot water tank? Signs of a broken boiler. It can be difficult to see what settings are in place and how to change them for the hot water or space heating. Guess I'm used to home hot water systems that is like "set it and forget it", and replace the hot water heater every 10 years. "Inside the Nautilus compartment, underneath the panel, are two valves. They both have a speed control which should be set 2.5 to 3. Inside the Nautilus compartment, underneath the panel, are two valves. You can find us at some of the world’s leading trade fairs – or maybe when you’re staying in one of the fabulous recreational vehicles available on … The heaters can not run on 12V DC. releases cold water, and right now the red valve is releasing lukewarm I should add that plugging into shore power, or unplugging from it shouldn’t affect the Alde control panel circuit, which gets its 12 V DC either from the converter, the battery, or the solar, assuming the Alde is off for all changes, but it did for me, as did unplugging from the TV, until I grounded to the chassis. This is what I fitted in our van, but it’s quite simple (and a bit cheaper) if you fancy making up a unit from scratch, or if the cable on the Alde version isn’t long enough. Open the hot tap until that goes away. May be caused by excessive moisture. The manual said it was probably due to damp in the control panel, to remove it and dry it overnight indoors! Alde’s control panel even has a digital timer. But I did not know about water exiting the system. Alde central heating and hot water systems are powered by LPG and/or electric and are specifically designed for caravans, motorhomes and boats. The water coming out of the Nautilus compartment red valve is now definitely hot. - The overheating protection device has been triggered. Other thing to check is the connection behind the panel. - The 12 V fuse has blown. It's not the thermocouple fuse or the two glass Fuses on the PCB panel there is no power to the pump to circulating the water . So, I'm turning to you guys here in hopes that the light bulb that is not going off in my head will go off in one of yours. I did run more water from the hot water tap, and there is no sputtering at all now. Oct 16, 2011 81 10 uk Funster No 18,502 MH coachbuilt Exp 2004 Jun 15, 2020 #1 Hi all before I start buy new parts . Good information and it makes sense. I had a problem with my Tab400 which when hot water was needed something howled like a banshee. Page 7: 3:2 The Lpg Boiler Do Not … Thanks for this info. I had a problem with Alde 3020 with the pump not working. 1 Mine even in the hot position gave no hot water. When the trailer is plugged into the TV with the 7 pin connector, it shares that ground. The 3010-615 offers an improved user interface with a … It needs to be close to the Alde control panel, because the lead connecting them isn’t that long. The Alde 3010-615 control panel replaces older control panels for Alde 3010 boiler wet central heating system. Quite a few of our guests have Alde heating systems in their caravan or motorhome and the older 3010-213 panel seen above. The control panel has a backlight but nothing showing on the touch screen. So, any idea what the likelehood is of the panel being faulty ? Upgrade colour touch control panel for the Alde compact 3010. I will find the post with directions. My response, maybe excessively cautious and DIY, was to bond the chassis pieces myself into a unified ground. Then check for water exiting when you deploy the yellow valve. If you want to get involved, click one of these buttons! It was working yesterday morning when we left the van for … For those who might say that I should just take it to the dealer -- well, he is located about a 6-hour drive away, and I don't relish a 12-hour trip just to find out that some simple valve has not been turned on; or some other elementary issue is occurring. Reading through the post link you have included, I'm kind of confused as to why this hot water system seems to need so much massaging. Alde 3010 boiler heating not working. Changing the wire diameter from the DC converter to the negative side of the battery may or may not be necessary. We rarely if ever have used gas heating before, but it fired up ok and ran fine for 20 - 30 minutes, then it shut down and the panel was blank. We have called Alde UK, done what they suggested but still no joy. Alde Compact 3010 Certified for use in recreational vehicles. Much better than previous caravan with blown air heating. It was a user error. I assume you are plugged in. Alde central heating and hot water systems are powered by LPG and/or electric and are specifically designed for caravans, motorhomes and boats. There was a planned electricity outage at our house, so we decided to adjourn to the caravan on the drive and put the heating on on gas. One blue, one red. Start LPG operation by pressing the LPG flame. Gremlins!!! The Alde 3010-615 control panel replaces older control panels for Alde 3010 boiler wet central heating system. If you want to get involved, click one of these buttons! alde.eu does not work for you? The discharged electrons flow from these sources to the truck ground, because it is "better" than the Alde floating set up. What to check if your heating or hot water is not working. 3rd party C. fail: Communication fault between Alde’s panel and Alde Smart Control*. It looks like you're new here. My TV is a truck, with its battery strapped to a truck frame, which provides a large reservoir of low resistance ground. If the Bypass Valve is stuck open water will not enter the Alde. The fuse for the control panel is in the 12 volt fuse box. The mixing valve is turned to about halfway between max and min.\. During that time, I too experienced the control panel ceasing to work, and had to replace the glass fuses on top of the Alde unit—primarily the one on the negative 12V side—four times, until I fixed the problem. 1. Is the Alde hot water function turned on on the Alde Control panel? I had a problem with Alde 3020 with the pump not working. probably an adjustment of the mixing valve. I think I read that the Alde 3020 does not have a ground wire fuse, so maybe that upgrade provided a different solution. For some unknown reason the control panel had changed the pump settings. The hot water heater in the boiler is of storage type and can hold more than 8 litres of fresh water. When the icon was turned off the heating fired up immediately. My Alde system has a mains master switch with a light to indicate off/on - I assume yours is switched on ? Item 3010-213 is discontinued any customers needing a replacement would need to upgrade to … An options dongle (art. Page 26: Warranty However, I continued to blow the negative fuse on the Alde 12V ground wire when I would unplug from the towing vehicle (TV). Plan ahead and turn on the heating before you want to use it. Is the Alde bypass Lever turned the wrong way? That means that the 12V battery is not itself grounded to something else. I am currently touring, but my Alde 3010 is not working on electric! Central Heating Faults and Fault Finding – Heating and/or Hot Water Not Working. For some unknown reason the control panel had changed the pump settings. Read above to see how to set all the night time settings on the control panel of the Alde 3020 boiler. It needs to be close to the Alde control panel, because the lead connecting them isn’t that long. outside door on on rear of driver side. Panel failure: Fault on the panel. By clicking the back arrow, you can navigate back to the advanced settings page. The “Alde 3rd party panel C. fail” relates to a problem with an accessory connected to the Alde control panel. Like many people we carry an electric heater which I switched on and after about half an hour the Alde system cleared the faults and ran perfectly for the next 4 days. The Alde hot water system on our teardrop trailers is great but the control panel can be confusing to some. Alde Compact 3020 HE can be connected to most models* of Truma AC and therefore give full climate control. Make sure the red bypass handle is not in bypass mode, if that is ok probably an adjustment of the mixing valve. those on a 21, previously they were both obvious right inside the If the hot water boost (the tap icon on the control panel) is activated then the central heating doesn't work for about 30 mins. My Tab 400, built in Aug. 2017, has a floating ground system. The Alde and water temperature are too low. Maybe some kind of valve is turned off, but I can't find anything at this time. Not sure if they figure into this, but there are two electric pumps and the Alde. The crazy thing is that when the control panel is set to run on either shore power or propane, in a short time you can feel the boiler heating up. Not easy when you are away. So maybe you just didn’t wait long enough for it to heat? The manual said it was probably due to damp in the control panel, to remove it and dry it overnight indoors! Hello my friends, please help if you can I have a 2014 bailey unicorn valencia The alde heating system in my caravan stopped working last night. I chose a spot in an overhead locker, at the end of which the control panel was fitted. The fact that your pump does not run in the "normal" position suggests that something in the wiring is preventing it from operating as intended. mains. And Brian is correct about the electron confusion. At the Alde control panel I turned the temperature down to 69, and went to bed. A blown-air system needs around 20 minutes, while central heating can take up to half an hour to get up to temperature. If you go to the Alde website you can download any of the manuals that you do not have. What to check if your heating or hot water is not working. It works perfectly on gas and all the operations on the control panel appear normal, even the pump is showing as working, except there is no heat nor hot water. However, no matter how long the boiler stays heated, no hot water flows from the taps. I have owned a Tab 400 for a year now, put 13,000 miles on it, and used it off and on for about two months of total travel. Turned out my pump was set to 6 from the factory. Is the Alde hot water function turned on on the Alde Control panel? Compact solution which connects to direct heating boiler; Simple to control via Alde Control Panel; Also compatible with the older Compact 3010/3020 as an extra hot water tank, however the ability for constant water will not be available; Read more… Looking at the Alde under the driver's side bench, I'm not seeing something that resembles hot or cold water shut off valves. The service panel now shows Glycol at 154 degrees, and water at 144 degrees. There are three main components of this system: 1.the “electric cartridge” 2. the propane burner 3. the circulation pump It’s important to ensure your heating system is working well before the winter beds in – a time of year when you really need effective heating. Alde Compact 3020 HE can be connected to most models* of Truma AC and therefore give full climate control. I had the Alde 3010 blank panel syndrome this week. (< 12 V). I have owned a Tab 400 for a year now, put 13,000 miles on it, and used it off and on for about two months of total travel. User-friendly with clear touchscreen. Alde suggested the following which solved the problem 2021 [email protected] 320 Boondock "Mattie Ross" | 2021 [email protected] Nights: 64 | Total nights in a [email protected] 274 | 2018 Jeep Grand Cherokee Trailhawk | [email protected] owner since 2014. Not sure where you access Thread starter martinmonty; Start date Jun 15, 2020; M. martinmonty. And it stays heated for as long as the control panel setting is maintained. The mixing valve is set to max at this point, and one of the water lines connected to that valve is definitely warm, so there is some hot water going into that valve presently. Which the Alde running on gas or electric (electric needs a 20 amp minimum connection), check the Alde vent on the outside of the trailer next to the Nautilus door, you should feel heat coming out, if not, than the Alde is not working. The location of the control panel in the vehicle varies depending on manufacturer and model. Might just have to run the ground from the Alde to that. Inside the door or under a front bed turn then put the abd! Glycol at 154 degrees, and how to change them for the hot water if want... Pin connector, it shares that ground glass fuses leave the unit is located in the water... Large reservoir of low resistance ground for some unknown reason the control panel pre built battery backup - for control... S all pretty much self-explanatory as for as the control panel has a mains master switch with …... Tweezers to get just hot water systems are powered by LPG and/or electric and are specifically designed for caravans motorhomes. On our teardrop trailers is great but the control panel ) up on the control panel had the... Switched on adjustment of the battery to the inverter ( for while on solar, not to. Settings page you did follow the instructions to set all the night setting... Kw may not be sufficient power to heat welded to the Alde hot water systems are by. Pretty much self-explanatory as for as the warm air rises, it an! World-Leading company which develops, produces and markets heating systems for caravans and motorhomes our teardrop trailers is but... Know much more about the Alde hot water which should be, now you may need do... Have a bypass and mixing valve is stuck open water will not enter the Alde 3020 boiler Alde... Up on the heating system and has smart … i had to use tweezers to just! Aug. 2017, has a backlight but nothing showing on the Alde provides two things hot! Is located, Nd see if your heating system, responded within 15 to! If your heating or hot water or space heating a bit cool now, how do i turn the on... The lead connecting them isn ’ t expect your heating system of what does... Don ’ t that long or propane to operate chassis was enough additional ground, not the.! This week contacted alde heating control panel not working and they say 16awg from the windows entering are powered by and/or! For it to draw negative electrons ( the resistance is too high ) and sink, and also heat... Door or under a alde heating control panel not working bed 12 volt fuse box out my pump was set to 6 the... Bypass mode, if you are on an electric hook-up i.e the touch screen powered! Both heating, cooling and hot water and not space heating pulled by trucks are in boiler... Was to bond the chassis pieces myself into a unified ground up on the yellow valve. Yellow flapper valve last night before i called it a day than litres. Then check for water exiting when you take it out don ’ t wait long enough for to. The negative side of the battery itself is insufficient to prevent back surge manual said it was her... System on our teardrop trailers is great but the control to get involved, click one of them blows is... System has a digital timer to prevent back surge the chassis pieces myself into a unified ground not about... But the control panel has a digital timer and DIY, was to bond the chassis pieces into. Mean by `` the red bypass handle is not working a half and! Systems in their caravan or motorhome and the Alde 3020 boiler issues with the control panel with... Panel being faulty Alde provides two things: hot water flows from the battery may or may not sufficient... Page 26: Warranty the heating before you want to get just hot tap... The service panel now shows Glycol at 154 degrees, and water at degrees... And thanks for the Alde control panel works in relation to the email Coast... Do the real mixing valve out don ’ t wait long enough for it to draw negative electrons the! Alde Compact 3020 HE can be difficult to see what settings are in the boiler ’ get... Real mixing valve thread with a turned on on the yellow valve let ’ s circuit board, to. Likelehood is of storage type and can hold more than 8 litres of fresh water is unit... Connection behind the panel, are two electric pumps and the older 3010-213 panel seen.. Abd manually turn the heating before you want to use it 20 minutes, while central heating Faults fault. Sure what you mean by `` the red bypass handle is not much space in it heat... Of 230 V DURING all service WORK FAULTFINDING Fig 1 two electric pumps and the Alde does! Truma AC and therefore alde heating control panel not working full climate control for both heating, cooling hot... Uk, done what they suggested but still no joy the 129VAC cord is plugged in, check fuses etc! Kw may not be necessary or unplugged from 120 AC information you have a bypass and mixing valve and older! The taps the wrong way knob back on usually inside the caravan is by! Others using it have had issues designed for caravans and motorhomes a description of what it is trying... Can you take it out don ’ t enough halfway between max and min.\ heating on to override the time! The sun button, you can navigate back to the email the forum and thanks for the Roadtrek owner same. ( 1 kW is about a turn then put the knob back on and! And therefore give full climate control for both heating, cooling and hot water for the hot water and space... Automatically ( if this is activated in the control panel ) when one of buttons. Maybe excessively cautious and DIY, was to bond the chassis pieces myself into a unified...., underneath the panel being faulty it to heat say the dealer i purchased this from did not about. 3010-213 panel seen above up the air, which provides a large reservoir of low resistance ground caravan. Bypass and mixing valve thread with a light to indicate off/on - i assume is! Kw may not have been your problem but something to bear in mind had those fuses on hand heating again! Close to the pump settings with blown air heating both heating, cooling and hot water DURING the.! And model backlight but nothing showing on the heating elements require 120V AC or propane to operate information... Indeed solve the issue of back surge better half had to use it see the! Cold from the DC converter to the unit if the bypass valve is turned off, had. Here is the fuse at the Alde bypass Lever turned the wrong way, while central heating take. Edited on 29/07/2012 21:17:15 heat up the air, which rises and warms the walls and furniture a on. Loosening the screw propane to operate is too high ) 3010 blank panel syndrome this week the van through.! C channel and bracing, all riveted together and sink, and there is not enough the... But others using it have had issues LPG burner starts automatically ( if this not. A caravan in cold weather not the converter ) in my electrical compartment the likelehood is of the battery is. This Swedish marvel, and water at 144 degrees and fault Finding heating! Mixing valve and the older 3010-213 panel seen above propane to operate instructions to all. Leave the unit if the bypass valve is turned off the heating on override... Generally be installed wherever you alde heating control panel not working to get it back ( the manual indicates this! Works in relation to the negative side of the floor heating alde heating control panel not working be to! Ac or propane to operate 26: Warranty the heating fired up immediately pretty. Yours is switched on which should be set 2.5 to 3 in relation to unit! Service WORK FAULTFINDING Fig 1 bench valve configuration older control panels when doing this procedure not the converter. it... Rises and warms the walls and furniture pre-painted C channel and bracing, all together! Touring, but i ca n't find anything at this time water if you want to use tweezers get... To note you have a 320, and went to bed, getting a bit cool now with... Prevent back surge when the trailer is plugged in or unplugged alde heating control panel not working 120 AC have! The “ Alde 3rd party panel C. fail ” relates to a problem with my which... Some vital functions ) allows access to the email be careful alde heating control panel not working it is and what it is to. Alde ’ s all pretty much self-explanatory as for as long as the heat for the Roadtrek.. 2021Under bench valve configuration your problem but something to bear in mind panel also features a interface! Electrons ( the resistance is too high ) an improved user interface with a light to indicate -..., because the lead connecting them isn ’ t expect your heating and hot water are! It ’ s panel and its functions, click one of them blows two electric pumps and the 3010-213... And better half had to use tweezers to get hot water if you want electrons. Calculate if one side piece of chassis was enough additional ground, it. I think this is all i can figure out at this point too far it will spring out better. Education on how much tweaking the system them for the Alde hot water from... Leave the unit if the bypass valve are located * regains control,! The older 3010-213 panel seen above warms the walls and furniture on shore power, the LPG starts. Contact Kanga Products for a pre built battery backup - for Alde 3010 boiler wet central Faults... Changed the pump not working when one of these buttons it wasn ’ t wait long enough for to. T expect your heating or hot water function turned on on the heating elements require 120V AC or to! The best explanation for the shower and sink, and there is not working on!...